Levelised cost of storage (LCOS) for batteries

Last updated .

Levelised cost of storage, or LCOS, is the lifetime cost of a battery, the capital, the running and the charging, divided by the energy it discharges across its life, both discounted to today. The result is a cost per megawatt hour that can be set against what a site would otherwise pay. Because it depends on how often the battery actually cycles, the figure is specific to the site.

The levelised cost of storage, or LCOS, is the average cost of storing and releasing one unit of energy across the whole life of a battery. It is worked out by adding up everything the battery costs over its life, the capital to install it, the cost to run it and the electricity used to charge it, and dividing that total by the amount of energy the battery delivers over the same period. The result is a figure in pounds per megawatt hour, which can be set against the price a site would otherwise pay to get that energy another way.

For a consultant comparing a battery against doing nothing, LCOS is the figure used for that comparison. If a battery stores and releases energy at a lower cost per unit than a site pays to buy and use that same energy without it, it clears the test on unit cost. LCOS gives that like-for-like cost per unit, but the investment decision still rests on payback and return as well. The figure that settles the comparison is specific to the site, because both halves of the sum depend on how the battery is actually used.

The two halves of the calculation

LCOS is a fraction, with the lifetime cost on top and the lifetime energy delivered on the bottom.

The lifetime cost has several parts. The largest at the start is the capital cost of the battery and its installation. On top of that sit the yearly operating costs: maintenance, and the cost of the electricity used to charge the battery, which is usually the biggest running item. Because a battery returns less energy than it takes in, every unit it delivers carries the cost of the extra unit lost to charging and discharging. Some long-lived projects also budget to replace or augment cells partway through, and a residual value at the end is subtracted from the total.

The lifetime energy delivered is the sum of every unit the battery discharges across its working life. This is where LCOS differs from a simple cost comparison, because the energy delivered is the energy the battery actually moves, which is less than the nameplate capacity times the number of days. How much it moves depends on how often it cycles and how much usable capacity it has left as the cells age.

Both halves are discounted, because a pound spent or a unit delivered in ten years is worth less than one today. UK public appraisal discounts future costs and benefits at a standard real rate of 3.5% a year for the first thirty years, set out in HM Treasury's Green Book. A commercial battery's life falls well inside that thirty-year window, so the same rate is a reasonable basis for discounting both its costs and its output, though a commercial appraisal often uses the investor's own cost of capital in place of the public rate.

A worked example

The figures here are invented and describe no real site. The example below leaves discounting out, so the structure of the calculation is visible before it is refined.

Suppose a battery costs £500,000 to install. Each year it costs about £30,000 to charge, after the charging losses are paid for, and £10,000 to maintain, so £40,000 a year. Over a fifteen-year life its lifetime cost is £500,000 plus fifteen years at £40,000, which is £1,100,000. Suppose it discharges about 700 MWh a year, roughly 10,500 MWh over the fifteen years. Its lifetime cost divided by that energy, £1,100,000 divided by 10,500 MWh, is about £105 per MWh. That is the number to compare against what the site pays to shift the same energy another way. Battery costs change from year to year: lithium-ion battery pack prices fell to a global average of $115 per kWh in 2024 (BloombergNEF), with a fully installed commercial system costing more than the cells alone once inverters and installation are added. That $115 per kWh is an upfront price for each unit of storage capacity, so it belongs in the capital cost on top of the fraction and is not comparable to the £105 per MWh LCOS, which is a cost per unit of energy delivered.

Discounting raises that figure rather than lowering it, because the capital is spent at the start and is barely discounted, while the energy is delivered across all the years that follow and so is discounted on average, which shrinks the denominator proportionally more than the cost total. Degradation works the same way: the battery delivers less in its later years as usable capacity falls, which trims the denominator further. A careful LCOS carries both effects, which is why the discounted figure for a real project runs above the rough undiscounted one above.

Why the energy delivered is not a nameplate number

The energy figure in the example was an assumption, and it is the assumption that most changes the answer. A battery cycled once a day at full depth would deliver, across a year, its usable capacity multiplied by the number of days. It never reaches that in service, for several reasons. Round-trip losses account for some of the gap, and the usable capacity falls as the cells age. Most of all, the battery only cycles when there is a worthwhile price spread or demand peak to work against, and on many commercial and industrial sites that spread is present on weekday peaks and largely absent at weekends and through the summer.

A battery that finds a profitable cycle most days delivers a large energy total and spreads its fixed capital cost across many units, so its cost per unit is low. A battery on a flat tariff with little to work against sits idle much of the year, delivers far less energy and carries a much higher cost per unit, even though the two batteries cost the same to install. The cycle count, and so the energy in the denominator, is a property of the site and its tariff rather than of the battery on its own. This is the same effect that governs whether a battery is worth installing.

Why the site's own dispatch settles it

Because the energy delivered depends on how the battery is run, an LCOS built on an assumed number of cycles a year is only as good as that assumption, and a round number such as one cycle a day rarely holds across a real year. The dependable way to get LCOS for a particular site is to work out how the battery would actually dispatch against that site's own half-hourly interval data and its real tariff, count the energy it discharges over the year, and divide the lifetime cost by that figure.

Dispatch worked out with perfect knowledge of future prices charges and discharges the battery at exactly the right moments, which overstates the energy a real controller reacting to forecasts can move, and so understates LCOS. A realism discount brings the modelled dispatch down to what is achievable in service, and the LCOS should be read off the discounted dispatch rather than the perfect-foresight one.

Lupa takes a site's own half-hourly data and electricity invoice, solves the dispatch for each battery size, counts the energy actually discharged across the year and reports the LCOS alongside the payback and the lifetime return. The platform does this for each combination of solar and storage, so a consultant can read the cost per unit a battery would really deliver on the site rather than one taken from an assumed cycle count.

Common questions

What is the difference between LCOS and payback?
Payback measures the time for a site's savings to cover the capital cost of the battery, so it answers how long the money is tied up. LCOS measures the average cost of storing and releasing one unit of energy across the whole life of the battery, so it gives a unit cost that can be set against the price of energy from another source. A consultant comparing a battery against doing nothing usually wants both: payback for the cash timing, LCOS for the like-for-like cost per unit.
What is a good LCOS for a commercial battery?
There is no single good figure, because LCOS depends on the install cost, the cost of charging, the asset life and, above all, how often the battery cycles across the year. A battery compares well when its LCOS sits below the cost the site would otherwise pay for the same shifted energy. That comparison is specific to the site's tariff and demand, so the figure that matters is the battery's LCOS on this site against its own tariff and demand.
Why does the number of cycles change the LCOS?
The energy the battery delivers sits in the denominator of the calculation. A battery that cycles more delivers more energy over the same life, which spreads a largely fixed capital cost across more units and lowers the cost per unit. A battery that only has a worthwhile price spread on some days cycles less, delivers less energy and carries a higher LCOS. The cycle count comes from the site's dispatch against its own tariff, so it has to be modelled rather than assumed from a nameplate.

Run it on your own site