What commercial solar panels cost per kW in the UK
Last updated .
Cost per kW has no single number: it falls as a system grows, because the fixed parts of a job spread across more capacity, and it moves with the roof, the access and how the capacity is measured. A commercial building also pays standard VAT. What matters is whether it pays back on the site's own data, something the headline rate cannot show on its own.
Commercial solar panels do not have a single cost per kW; the honest first answer to anyone pricing a rooftop system is a range. As a rough public benchmark, the Renewable Energy Hub's commercial solar cost estimates, updated in January 2026, run from £25,000 to £35,000 for a 25 kW system up to £750,000 to £1,000,000 for a 1 MW system, which is roughly £1,000 to £1,400 per kW at the small end and £750 to £1,000 per kW at the large end. The cost per kW falls as the system grows, so a small rooftop array costs more per kW than a large one, and it moves with the building, the roof and the state of the grid connection. A more authoritative public series is the installed cost per kW that the Department for Energy Security and Net Zero publishes each year in its solar PV cost data. That figure is a historic average across many installations, so it serves better as a broad benchmark than as the price of any one roof. The same job can also be stated at more than one cost per kW depending on whether the price is divided by the panel rating or the lower inverter rating, so a quoted rate means little until you know which it uses.
What "per kW" is actually counting
A cost per kW is a total divided by a capacity, so the capacity on the bottom of that sum changes the answer. A solar array has two ratings that can sit there. The panel rating, in kWp, adds up the direct-current ratings of the panels, the most they could produce under standard test conditions. The inverter rating, in kW or kVA, is the alternating-current output the inverter can deliver to the building, and it is usually the lower of the two, because inverters are commonly sized below the panel total. Dividing the same installed price by the larger panel rating gives a lower cost per kW than dividing it by the inverter rating. When a quote states a figure per kW, the first thing to establish is which rating it uses, since the same job can be presented either way.
Why the figure falls as the system grows
Every solar job includes costs that do not scale with the number of panels: the design and the survey, the scaffolding or access equipment, the grid connection application and any work the network operator requires, the inverter housing and the cabling back to the board. These are set more by the fact of doing the job than by its size, so they are divided across whatever capacity is installed. The more capacity they are divided across, the smaller their contribution to each kW, and the cost per kW falls accordingly. The panels, mounting and labour that do scale with size sit on top, but the fixed share alone is enough to lower the cost per kW steeply as the array grows, which is why a figure taken from a small installation is a poor guide to a large one, and why cost per kW is quoted against a size band.
What the building and the site add
Beyond size, the cost per kW moves with the building it sits on. A standing-seam metal roof takes clamps and goes quickly; a fragile or asbestos roof, or one that needs strengthening to carry the load, costs more for the same capacity. A tall building, or one where the panels sit far from the switchroom, adds access and cabling. The grid connection can be the largest variable of all: a site with spare capacity connects cheaply, while one that needs the network reinforced can face a bill far larger than the panels themselves. None of these show in a headline rate, and each of them affects the cost per kW for the specific site.
VAT on a commercial installation
One cost that applies on top of the installed price is VAT, and here a commercial building is treated differently from a home. HMRC sets a zero rate for energy-saving materials that covers installing solar panels, running in Great Britain from 1 April 2022 and in Northern Ireland from 1 May 2023, in both cases to 31 March 2027, but it is limited to residential accommodation and buildings used for a relevant charitable purpose; after 31 March 2027 it falls to a reduced rate of 5% for those same buildings. A solar installation on an ordinary commercial premises falls outside the relief and is charged VAT at the standard rate of 20%. A VAT-registered business can usually recover that, but it still sits in the up-front cost and the cash flow, so it belongs in any cost-per-kW comparison between a commercial site and a domestic one.
Why the real cost depends on the site
Because the cost per kW depends on the size, the roof, the site and the way capacity is counted, an average taken across many installations is a weak guide to any one of them. A firm number comes from quotes for the specific roof. What those quotes are worth is a separate question, because a cost per kW is informative only once it is set against the saving the system produces.
That saving comes from the generation the site uses in place of imported power and the network charges it avoids, so it depends on the site's demand and its tariff more than on the price of the panels. The way to answer it is to model the proposed array against the building's own half-hourly interval data and its actual tariff, which shows how much of the generation the site would use, set out in the guide to self-consumption, and how quickly the outlay comes back, set out in the guide to payback.
Lupa takes a site's own half-hourly data and electricity invoice and models the generation, the saving and the payback for each combination of solar and storage. See the platform.
Common questions
- Is there a standard cost per kW for commercial solar in the UK?
- There is no standard figure: cost per kW falls as the system grows, because the fixed parts of a job spread across more capacity, and it moves with the roof, the access and the grid connection. It also depends on whether the quoted capacity is the panel rating or the lower inverter rating. A figure for a specific roof comes from quotes for that roof, not from an average across many sites.
- Why do two quotes for the same system show different costs per kW?
- Often because they divide the price by different capacity ratings. The panel rating, in kWp, is the direct-current total of the panels, while the inverter rating is the lower alternating-current output. Dividing the same price by the larger panel rating gives a lower cost per kW, so one job can be presented at two different rates. Establishing which rating each quote uses makes them comparable.
- Does a commercial building pay VAT on solar panels?
- A commercial building usually pays the standard rate. The temporary zero rate for solar is limited to residential accommodation and relevant charitable buildings, so an ordinary commercial premises falls outside it and its installation is charged at the standard rate. A VAT-registered business can usually recover that, but it still sits in the up-front cost, so it belongs in any comparison with a domestic installation.
Run it on your own site
Lupa models a building from its own half-hourly data and the tariff it actually pays, and sizes solar and battery storage against both.